Abstract

The purpose of this study is to assess sources of contamination by analyzing the free product and oil compounds in groundwater near the Subway Station, located adjacent to the Yongsan Garrison in Seoul, Republic of Korea. All of the samples collected twice were groundwater and free product in a monitoring well. Analysis items are TPH fingerprinting, pristine/phytane ratio, alkylbenzene pattern, PAH&alkyl PAH, antioxidant, icing inhibitor, PIANO, element(C, N, H), and sulfur. Using ratio of pristine/phytane, we were able to distinguished fuel type between kerosene and JP-8 samples, which was impossible by GC/FID pattern. Alkyl benzene pattern was very effective in distinguishing between JP-8 and kerosene. It is very important that 2,4-dimethyl-6-tert-butyl phenol, an antioxidant used only for JP-8, was detected in free product samples. The concentration of sulfur in kerosene fuel is much lower than that of JP-8, and the total contents of sulfur in environmental samples can be used to differentiate the fuel type of spilled oil between kerosene and JP-8. In conclusion, according to the result of a variety of analytical methods to find the source of spilled fuel, it had been found that the fuel type detected in the tunnel of subway station and monitoring wells outside of Yongsan Garrison and the monitoring wells inside of Yongsan Garrison are the same.